RAID Storage Calculator - RAID 0/1/5/6/10 Capacity Calculator Free

Free online RAID storage calculator. Calculate usable capacity for RAID 0, 1, 5, 6, and 10 configurations. Enter drive count and size to see total, usable, and fault tolerance.

Advertisement

Loading tool...

Advertisement

How to Use the RAID Calculator

  1. Select RAID level — choose from RAID 0, 1, 5, 6, or 10
  2. Enter number of drives — the minimum varies by RAID type (e.g., RAID 5 needs at least 3 drives)
  3. Enter drive capacity — input the capacity of each drive in TB or GB
  4. View results — usable capacity, total raw capacity, fault tolerance, and storage efficiency percentage
  5. Compare levels — switch between RAID levels to see how the numbers change with the same drives

Perfect for system administrators, CCTV installers, and IT professionals planning storage for NVRs and servers.

Features

  • All common RAID levels — RAID 0 (striping), RAID 1 (mirroring), RAID 5 (striping with parity), RAID 6 (dual parity), and RAID 10 (mirror + stripe)
  • Real-time calculation — results update instantly as you change inputs
  • Fault tolerance — clearly shows how many drives can fail without data loss for each RAID level
  • Storage efficiency — displays the percentage of raw capacity that is usable
  • Performance notes — summarizes read/write characteristics and advantages of each RAID type
  • Minimum drive validation — warns if the drive count is below the minimum for the selected RAID level

Use Cases

NVR storage planning — CCTV installers with a 16-channel NVR need to calculate how much video retention time different RAID configurations provide. The calculator helps compare RAID 5 (efficient, single-drive fault tolerance) vs RAID 6 (dual-drive fault tolerance for longer rebuild times) using the same set of drives.

Server deployment — system administrators planning a file server or database server calculate usable storage across multiple RAID levels. They compare RAID 10 for performance-critical databases against RAID 5 for bulk file storage using the same hardware budget.

Home media servers — enthusiasts building a NAS for Plex or home media use the calculator to decide between RAID 5 (better capacity efficiency) and RAID 1 (simpler, better redundancy) for a 4-bay system.

IT budgeting — when purchasing storage, the calculator helps determine how many drives are needed to achieve a target usable capacity with the desired level of redundancy.

FAQ

What is the difference between RAID levels?

RAID 0 splits data across drives for maximum speed but has no redundancy — one drive failure loses everything. RAID 1 mirrors data for full redundancy but uses 50% of raw capacity. RAID 5 uses one drive’s worth of parity for single-drive fault tolerance at ~80-90% efficiency. RAID 6 uses two parity drives for dual-drive fault tolerance. RAID 10 mirrors striped sets for both performance and redundancy.

Which RAID level is best for security camera NVRs?

RAID 5 is the most common choice for NVR storage. It provides single-drive fault tolerance (important for continuous recording) with good capacity efficiency. For larger arrays (8+ drives), RAID 6 offers extra protection since rebuild times are long and a second drive failure during rebuild is possible.

How many drives do I need for each RAID level?

RAID 0 needs at least 2 drives. RAID 1 needs exactly 2 drives. RAID 5 needs at least 3 drives. RAID 6 needs at least 4 drives. RAID 10 needs at least 4 drives (in pairs).

What happens if a drive fails in a RAID array?

In RAID levels with redundancy (1, 5, 6, 10), the array continues operating in a degraded state. The failed drive must be replaced and the array rebuilt from parity data. During rebuild, performance is reduced and the array is vulnerable to a second drive failure (except RAID 6).

What is “fault tolerance” in RAID?

Fault tolerance refers to how many drive failures the RAID array can survive without data loss. RAID 0 has 0 fault tolerance. RAID 1 and RAID 5 tolerate 1 drive failure. RAID 6 tolerates 2 drive failures. RAID 10 can tolerate multiple failures as long as no mirrored pair loses both drives.

Tips

  • For RAID 5, consider using drives of the same capacity — the array is limited by the smallest drive
  • RAID 6 is strongly recommended for arrays with 8+ drives due to the risk of URE (Unrecoverable Read Error) during rebuild
  • Always maintain a spare drive (hot spare) to minimize the time the array operates in degraded mode after a failure